NRG BP65 Barometric Pressure Sensor
DETAILS
The NRG BP65 Barometric Pressure Sensor is well-suited for the barometric pressure measurement requirements of remote wind and solar energy studies, particularly as an input to air density and annual energy production calculations. Its durable housing protects the high accuracy sensing element, providing reliable operation in a variety of climates and conditions.
Each BP65 unit undergoes a single-point check to confirm performance within the sensor’s specifications, the results of which are available in a factory verification certificate at no additional cost. A three-point calibration is also available.
The BP65 maintains the proven design of its predecessor, the BP60, ensuring seamless transition to this next generation sensor.
*Please note: BP65C is the calibrated version of this sensor.
Benefits
- High accuracy at an economical price point
- Native temperature-compensation allows the sensor to react to internal temperature changes almost immediately
- Well-suited for remote wind and solar energy studies with low, 1 mA current draw
- Designed to be a drop-in replacement for the BP60 for seamless transitions
- Cable lengths up to 110m and an optional up-tower bracket provide flexible mounting options
SPECIFICATION
| 1.5M CABLE (#19126) | 1.5M CABLE, CALIBRATED (#19127) | 67M CABLE (#19128) | 90M CABLE (#19129) | 110M CABLE (#19130) | |
|---|---|---|---|---|---|
| Description | |||||
| Sensor type | n/a | Analog barometric pressure sensor based on piezo resistive silicon membrane | n/a | Analog barometric pressure sensor based on piezo resistive silicon membrane | Analog barometric pressure sensor based on piezo resistive silicon membrane |
| Applications | n/a |
|
n/a |
|
|
| Sensor range | n/a |
|
n/a |
|
|
| Signal conditioning module | n/a |
|
n/a |
|
|
| Input signal | |||||
| Signal type (sensor output) | n/a | n/a | n/a |
|
n/a |
| Output signal | |||||
| Signal type | n/a |
|
n/a | n/a |
|
| Transfer function | n/a |
|
n/a |
|
|
| Accuracy | n/a | Uncertainty (k = 2):
|
n/a | Uncertainty (k = 2):
|
Uncertainty (k = 2):
|
| Electrical time constant | n/a |
|
n/a |
|
|
| Calibration | n/a |
|
n/a |
|
|
| Output signal range | n/a |
|
n/a |
|
|
| Turn on time | n/a |
|
n/a |
|
|
| Resolution | n/a |
|
n/a |
|
|
| Drift | n/a |
|
n/a |
|
|
| Power requirements | |||||
| Supply voltage | n/a |
|
n/a |
|
|
| Supply current | n/a |
|
n/a |
|
|
| Installation | |||||
| Mounting | n/a |
|
n/a |
|
|
| Tools required | n/a |
|
n/a |
|
|
| Accessories | n/a |
|
n/a |
|
|
| Wiring | n/a | Wire leads:
|
n/a | Wire leads:
|
Wire leads:
|
| Environmental | |||||
| Operating temperature range | n/a |
|
n/a |
|
|
| Operating humidity range | n/a |
|
n/a |
|
|
| Lifespan | n/a |
|
n/a |
|
|
| Other | n/a |
|
n/a |
|
|
| Physical | |||||
| Cable length | n/a |
|
n/a |
|
|
| Weight | n/a |
|
n/a |
|
|
| Dimensions | n/a |
|
n/a |
|
|
| Materials | |||||
| Cable | n/a |
|
n/a |
|
|
| Enclosure | n/a |
|
n/a |
|
|